Professional technology of dry transformer dust removal

Professional technology of dry transformer dust removal

2022-11-04
      There are still dust when the dry transformer is used, and the dust removal of dry transformers also has many ways. What are the more common professional techniques of dry transformer dust removal? How does it perform dust removal? Let's take a look with Hengfeng You Electric Engineering Co., Ltd..
      Dry transformers are generally used in local lighting, multi -layer buildings, airfields and port CNC industrial equipment. Simply put, dry transformers refer to the transformer that is not immersed in the transformer oil in the transformer, and the oil -soaked transformer is not immersed in the transformer oil, and the oil -immersed transformer Compared with the fire resistance of dry transformers, it is mostly used for places with high requirements for fire safety. For example Regulations; not too wet and cold, not too much dust and dirt, avoid wet and cold and dust caused damage to dry transformers, and reduce the use of dry transformers.
      Dry transformers and oil immersion. The transformer uses more than two variable electrical appliances. Compared with oil -soaked transformers, the dry -type transformer is more refractory. The airport, subway station and other places, but the price is higher in comparison, and there are certain regulations on the surrounding environment. For example, you cannot be too wet and cold, and you cannot have too much dust and dirty.
In order to achieve the above practical new type of patent, the technical specifications used by the practical new patent are:
      A dry transformer with high efficiency dust removal includes: base, refrigeration cylinder, vacuum device and automatic brush. The above base is provided with a lower groove, and the above base is provided with centrifugal fans for refrigeration dry transformers. The above grooves and bases are equipped with automatic brushes caused by the dust caused in the centrifugal fan. The above automatic brush is composed of rotating rods and anti -static hair brushes. There is a refrigeration cylinder on the bottom groove. There are low -voltage electromagnetic coils on the side, high -voltage ignition lines on both sides of the refrigeration cylinder, one end of the fixed rod on both sides of the high -voltage ignition line, the above high -voltage ignition line is provided with a groove. There is a vacuum device and high -pressure terminal, and the above high -pressure terminal is fixed at the other end of the fixed rod.
Further, the above rotation rod is surrounded by mesh eyes for putting anti -static hair brushes.
Further, the above -mentioned vacuum device internal internal decaptery -downtime activated carbon filter, the above -mentioned vacuum device externally connected to the mesh structure protective cover.
Further, the above automatic brush power is connected to a centrifugal fan.